VIIRS Fire Sample Assets

VIIRS 火点样本资产库 · 人工审核证据图全库
Guangzhou Meteorological Satellite Ground Station (GZMSS) · 广州气象卫星地面站(广东省气象卫星遥感中心)
Contact / 联系:jinyb_gzmss@yeah.net

About / 关于本库

Confirmed fire sample with smoke plume 真火冒烟样本审核图

A human-reviewed sample library for VIIRS active-fire detection research: confirmed real fires paired with hard negatives that operational fire products commonly confuse with fires (industrial heat sources, photovoltaic plants, hot surfaces, heated water, volcanoes, and more). Every sample carries a multi-panel evidence figure used during label auditing. Snapshot: 2026-09-14, 63,714 reviewed samples.

Beyond the training library, the archive also hosts the omission case pool: 953 fire events human-confirmed as missed by the operational VIIRS active-fire product (finalized 2026-09; night stratum n=382), each carrying the multi-source evidence figure used in per-case interpretation. Cases fall into four analyst-interpreted groups — cloud-related (65), weak-signal (357), bowtie-censoring (156) and strong-signal (375); the grouping reflects per-case judgement of the dominant observation limit, not ground-truth mechanism classes.

本库为 VIIRS 火点反演研究配套的人工审核样本资产:真火样本与易被业务火点产品误判的 难负样本(工业热源、光伏、高温地表、水面固定热源、火山等)成对构建,每个样本均附审核证据图。快照日期 2026-09-14,人审样本 63,714 个。完整索引与数据张量将随论文发表公开。

训练样本库之外,本站另存漏报案池:经人工确认被业务 VIIRS 火点产品漏报的 953 起火点事件(2026 年 9 月定稿;夜间层 382 案),每案附人工逐案判读所用的多源证据图。案池按判读分四组—— 云相关(65)、弱信号(357)、bowtie 删失(156)、强信号(375);分组为逐案判定的主要观测限制,不是真值机制类别。

How the database was built / 数据库是如何构建的

The figures below (from our manuscript, under review) summarize how the sample database and evaluation references were constructed. / 下图(引自本组在审稿件)概括样本数据库与评估参照的构建方式。

Sample library and omission pool construction 样本库与漏报案池构建流程
Supplementary Fig. S1 · Sample-library & omission-pool construction 样本库与漏报案池构建流程: module 1 builds the 64,418-sample development library (39,995 target fires + 24,423 negatives) through machine-assisted evidence pre-screen (Kimi K3), human review and event-level split; module 2 screens the separate 953-case omission pool from the same observations (609,762 → 9,363 → 5,048 → 1,093 → 953), removing 15 cases that duplicate training positives, and assigns the pool to four interpretation groups (strong-signal 375 · weak-signal 357 · bowtie-censoring 156 · cloud-related 65) whose evidence panels are hosted on this site. 模块 1——机器预审核(Kimi K3)+ 人工审定 + 按事件划分,构建 64,418 样本开发库(39,995 正 + 24,423 负); 模块 2——基于同源观测筛出独立漏报案池 953 案(609,762 → 9,363 → 5,048 → 1,093 → 953,剔除与训练正样本重复 15 案), 按判读分四组(强信号 375 · 弱信号 357 · bowtie 删失 156 · 云相关 65),各案证据图均存于本站。点击图片放大 / click to zoom。
Study area and sample composition 研究区与样本构成
Fig. 2 · Study area & sample composition 研究区与样本构成: 64,418 human-reviewed training samples (2018–2025) — 39,995 target fires and 24,423 negatives (10,892 heat-source negatives in five classes, with stationary open burning including 29 volcanic detections, plus 13,531 background negatives combining ordinary backgrounds with non-fire water, cropland and urban samples) — plus the separate 953-case omission pool. 64,418 个人审训练样本(2018–2025)——目标火 39,995、负样本 24,423(五类热源负样本 10,892,其中露天固定燃烧含火山热点 29;背景负样本 13,531,由干净背景与水体、农田、城市等非火样本合并显示)——另有独立漏报案池 953 案。

Note / 说明:figure numbers follow the manuscript under review (Supplementary Fig. S1 and Fig. 2, final training-database caliber); the archive table below is the evidence-figure snapshot (2026-09-14), so a few category counts differ slightly. 图中数字为稿件训练库定稿口径(附图 S1 与正文图 2),下方档案表为证据图快照口径(2026-09-14),个别类别数略有出入。

Browse the archive / 浏览下载

Category / 类别Content / 内容Items / 数量
fire/day · fire/nightConfirmed fires (day/night) 确认真火(昼/夜)38,756 / 963
industrialIndustrial heat sources 工厂/工业热源6,692
pvPhotovoltaic plants 光伏1,305
open_persistent_burningOpen / persistent burning 露天固定燃烧1,729
hot_surfaceHigh-temperature roofs / hot surfaces 高温屋顶地表290
urbanUrban / industrial mix 城市混合区277
croplandCropland (non-fire) 农田(非火)1,590
waterWater bodies 水体3,712
heated_waterHeated water / offshore sources 水面固定热源848
volcanoVolcanic activity 火山29
backgroundClean background 干净背景7,955
omission_pool · strong signal / weak signal / bowtie scanning artifact / cloud obstruction Fire events missed by the operational VIIRS product (separate case pool, not training samples) 业务产品漏报案池(独立案池,非训练样本)375 / 357 / 156 / 65

Documentation / 文档:README.md · METHODOLOGY.md(图件生产管线与口径)· Usage statistics / 访问统计:stats.html

Model release / 模型发布

The fire-discrimination model built on this sample library is now public: VS2-UNet-NegCap1 — a two-branch network (27-channel VIIRS thermal trunk + pre-event Sentinel-2 conditioning via FiLM), 727,666 parameters, released with full input specification and an annotated away-2020 benchmark (ours 94.7 / 90.3 / 62.2 / 59.4 % vs operational VIIRS 95.3 / 78.0 / 54.9 / 22.7 % fire-pixel coverage at 750 m on four primary comparison scenes).

基于本样本库构建的火点判别模型现已公开:VS2-UNet-NegCap1 双支路网络 (VIIRS 27 通道热主干 + 事件前 Sentinel-2 条件注入),公开训练权重、输入规格与 away-2020 标注基准(四个主要对比景;场景与人工标注取自 Fusioka et al. 2024 公开数据集,详见模型发布页致谢)。 代码 MIT · 权重 CC BY-NC 4.0 · 基准 CC BY 4.0。

→ Enter the model release page / 进入模型发布页

Download speed is capped at ≈250 KB/s (shared by all visitors) to keep the server responsive — large batches may take a while. Thank you for your patience.
本站全局限速约 250 KB/s(所有访客共享),批量下载请耐心等待。访问与下载匿名统计仅用于服务改进。

Maintainer / 维护人

Yinbao Jin 晋银保
晋银保 / Yinbao Jin 工程师 · 博士(Engineer, Ph.D.)
Guangzhou Meteorological Satellite Ground Station (GZMSS) · 野火 · 生物质燃烧排放清单 · 气溶胶–火相互作用
→ Full profile & publications / 个人主页与论文列表